Home About Design Installation Stakeholders Proven Results Specifications Contact Distributors

SCOURSTOP INSTALLATION QUIZ HISTORY AND DETAILS

Quiz Date: 01/16/2010 00:24:49
Correct: 18

11) Downstream flows, Scour area, and backslopes all need to be dealt with as a result of NPDES’s_______?
You got this question correct!

12) Which of the below eliminates maintenance, filters pollutants, facilitates groundwater recharge, and mechanically protects the soil downstream?
You got this question correct!

13) The minimum anchor depth in cohesive soils is 18" for proper installation of ScourStop. What is the minimum # of anchors and minimum anchor depth for non cohesive soils?
You got this question incorrect!

14) Which of the below applications is not proper for a vegetated ScourStop application?
You got this question incorrect!

15) ScourStop can be used to prevent erosion at slope changes upon an extended runoff. It also secures TRMs to the existing soil profile, preventing breakthrough erosion under the TRMs.
You got this question correct!

6) ScourStop may abut or overlap the discharge area.
You got this question correct!

7) Slope changes greater than 25% off the end of pipes and openings are not recommended due to impact erosion and waterfall effects.
You got this question correct!

8) Whatever the application, installing the anchor in a solid soil foundation is mandatory.
You got this question correct!

9) A “French drain” is recommended for which of the following:
You got this question correct!

10) Which of the answers below is not part of ScourStop’s Anchoring System?
You got this question incorrect!

11) Downstream flows, Scour area, and backslopes all need to be dealt with as a result of NPDES’s_______?
You got this question correct!

12) Which of the below eliminates maintenance, filters pollutants, facilitates groundwater recharge, and mechanically protects the soil downstream?
You got this question correct!

13) The minimum anchor depth in cohesive soils is 18" for proper installation of ScourStop. What is the minimum # of anchors and minimum anchor depth for non cohesive soils?
You got this question incorrect!

14) Which of the below applications is not proper for a vegetated ScourStop application?
You got this question incorrect!

15) ScourStop can be used to prevent erosion at slope changes upon an extended runoff. It also secures TRMs to the existing soil profile, preventing breakthrough erosion under the TRMs.
You got this question correct!

16) Which of the following is a reason for failure for a ScourStop Stormwater Treatment Practice?
You got this question correct!

17) Non cohesive soils are sandy and crumbly. A geotextile is often recommended as one of the soil covers in the specification for non cohesive soils.
You got this question correct!

18) It is acceptable to suggest that ScourStop wouldn’t work in certain applications.
You got this question correct!

19) In an installation of lower volumes and velocities, which of the following is used in conjunction with ScourStop?
You got this question incorrect!

20) ScourStop is used at the toe and base of a slope to prevent_____________?
You got this question correct!

21) Which of the following ScourStop installation types should be used when handling flow rates greater than 12 feet/second through a large culvert and over bare soil?
You got this question correct!

22) ScourStop is proven up to _______/square foot of shear.
You got this question correct!

23) When installing ScourStop with no overlapping, a minimum of ___________ anchors per mat is required for proper installation.
You got this question incorrect!

24) ScourStop may be used as a temporary or permanent solution to erosion and sediment transfer.
You got this question correct!

25) When installing ScourStop over sod, the sod is recommended to be cut down to a height of how many inches.
You got this question correct!

26) It is appropriate to install an anchor in each corner of a ScourStop mat?
You got this question incorrect!

27) Installer checklists tell the crew foreman how much material to use.